We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
LR-TB2000
Type
Mounting bracket
Description
Sensor Anwesenheit von Paketen im Geschäft
Stock availability:
On request
Contact us to get a great deal on Keyence . We supply only new gear Keyence directly from the producer, therefore we can offer the most attractive price and a quality guarantee. FAMAGA sells only certified products and gives an official guarantee from the fabricator Keyence.
Our specialists speak your language. In a short time they will find for you Keyence at an attractive price, find your desirable spare parts and accessories for Keyence , will recommend counterparts and agree delivery time to the doors of your company.
Perfect system of delivery allows us to deliver gear to any city in South Africa or any point of the world for the delivery chosen by you in a short time South Africa, Botswana, Namibia, Zimbabwe, Mozambique, Madagascar, Yemen, Sierra Leone, Iraq, Congo, Central African Republic, Libya, Georgia, Egypt, Chile, South Korea, Liechtenstein, San Marino, Singapore, Italy, Bolivia, Vietnam, Antigua and Barbuda, Burundi, Angola, Thailand, Papua New Guinea, Turkey, Honduras, Saudi Arabia, Mexico, Eswatini, Lebanon, Andorra, Uganda, Poland, Pakistan, Kiribati, Bhutan, Afghanistan, Palestine, Uzbekistan, Mauritania, Grenada, Slovakia, Malaysia, Cyprus, Myanmar, Burma, Gabon, Haiti, Niger, United Arab Emirates, Paraguay, Bosnia and Herzegovina, Mongolia, Kenya. If you become our constant customer, you will get even more attractive terms of delivery.
Our company has been working in South Africa for over eight years, supplying gear to over 17500 clients all over the earth. Our clients are over 2600 large corporations with world names.
If extra information is needed please contact us, E-mail us vendor code or description of needed goods.
Model | LR-TB2000 | |
Type | Cable | |
Detectable distance | 60 to 2000 mm*1 | |
Spot diameter | Approx. 4 mm | |
Response time | 1 ms/10 ms/25 ms/100 ms/1000 ms selectable | |
Light source | Type | Red laser (660 nm) |
Laser class | Class 2 laser product (IEC60825-1,FDA (CDRH) Part1040.10*2) | |
Mutual interference prevention function | 4 units (when using the interference prevention function) | |
Timer | OFF/OFF delay/ON delay/One-shot | |
Power voltage | 20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS | |
Current consumption | 45 mA or less (without load)*3 | |
I/O | Control output | NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, residual voltage: 2 V or less, N.O./N.C. selectable *4*5 |
External input | Switchable between transmission OFF, teaching, and reference surface update Short-circuit current: 1 mA or less for both NPN and PNP For the applied voltage, see the wiring diagrams (pages 2 and 3 in the instruction manual). For the input times, see the time charts (page 4 in the instruction manual).*6 | |
Analogue output | - | |
Protection circuit | Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge | |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Ambient light | Incandescent lamp/Sunlight: 10,0000 lux or less | |
Ambient temperature | -20 to +55 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |
Material | Case: Zinc die cast (Nickel chrome plating), Indicator cover and buttons: PES, Lens cover and display: PMMA (scratch-resistant coating specifications), Cable bushing: PBT, Cable: PVC | |
Accompanying items | Instruction manual, Laser warning and explanation labels | |
Weight | Approx. 125 g (Including cable) | |
*1 The range for displayable distance is from 50 to 2200. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 145 mA or less (with load) *4 You can select the I/O from the following combinations. Control output ? 2, control output + external input Control output + analogue output (LR-TB5000/TB5000C/TB5000CL only), External input + analogue output (LR-TB5000/TB5000C/TB5000CL only) (For details on the setting method, see the instruction manual.) *5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office. *6 You can select the I/O from the following combinations. Control output ? 2, control output + external input, IO-Link (For details on the setting method, see page 3 of the instruction manual.) |