We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.
Contact us to get a great deal on Keyence . We supply only new industrial machinery Keyence directly from the producer, therefore we can offer the most attractive price and a quality guarantee. FAMAGA sells only certified equipment and gives an official guarantee from the producer Keyence.
Our specialists speak your language. In a short time they will find for you Keyence at a competitive price, find your desirable spare parts and accessories for Keyence , will recommend counterparts and agree delivery terms to the doors of your company.
Outstanding delivery network allows us to send industrial machinery to any city in South Africa or any point of the world for the delivery chosen by you in a short time South Africa, Botswana, Namibia, Zimbabwe, Mozambique, Madagascar, Grenada, Monaco, Oman, Portugal, Guyana, Cameroon, Turkey, Myanmar, Iceland, Iraq, Latvia, Azerbaijan, New Zealand, Brazil, Eritrea, El Salvador, Afghanistan, Eswatini, Pakistan, Montenegro, China, Sweden, Tanzania, Sierra Leone, Congo, Armenia, Cyprus, Poland, India, Vietnam, Colombia, Honduras, Kyrgyzstan, Paraguay, Thailand, Gabon, Venezuela, Andorra, Mexico, Kenya, Chile, Uzbekistan, Philippines, Mongolia, Panama, Antigua and Barbuda. If you become our constant buyer, you will get the most satisfying terms for future cooperation.
Our company has been working in South Africa for over eight years, supplying industrial machinery to over 19000 clients around the globe. Our clients are over 2500 large corporations with world names.
For prices and delivery terms please contact us, E-mail us vendor code or description of needed goods.
Model | SL-C60HG | ||
Effective aperture angle | Max. ±2.5 ° (when operating distance is at least 3 m) | ||
Response time | 15 ms *1 | ||
Light source | Infrared LED (850 nm) | ||
Operation mode | Turned on when light is being applied to all optical axes (excluding when the blanking function is used) | ||
Detection capability | o25 mm (when the blanking function is not used) | ||
No. of beam axes | 60 | ||
Detection zone | 1180 mm | ||
Protection area | 1225 mm | ||
Detectingdistance | 0.3 to 9 m | ||
Beam axis interval | 20 mm | ||
Lens diameter | o5mm | ||
OSSD output | Output type | 2 outputs each for PNP and NPN, Can be switched using the connection connector cable | |
Max. load current | 300 mA *2 | ||
OFF-state voltage | 2.5 V (with a cable length of 7 m) | ||
Leakage current | 100 µA maximum*3 | ||
Max. capacitive load | 2.2 µF (with a load resistance of 100 ?) | ||
Load wiring resistance | 2.5 ? maximum*4 | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 Class A, FCC Part15 Class A | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (type 4 ESPE),IEC61496-2, EN61496-2, UL61496-2 (type 4 AOPD),UL508 | ||
Current consumption | Transmitter | 97 mA | |
Receiver | |||
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less | |
Environmental resistance | Enclosure rating | IP65 (IEC60529) | |
Ambient light | Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -10 to +60 °C (No condensation | ||
Operating relative humidity | 35 to 85 % RH (No condensation) | ||
Storage relative humidity | 35 to 95 % RH (No condensation) | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Weight | Transmitter | Approx 750 g | |
Receiver | Approx 825 g | ||
*1 OFF>ON return time is 125 ms. *2 Note the derating illustrated in the graph to the right when using PNP output. *3 This includes situations in which the SL-C Series is off and in which the power supply line is disconnected. *4 The wiring resistance between the OSSD output and the connected equipment (excluding the wiring resistance of the optional dedicated cable) must be 2.5 ? or less to ensure that the SL-C Series operate correctly. If using the NPN output |