IFM SI5100
  IFM SI5100

We are not the manufacturer, authorised distributor or authorised representative of the IFM brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.

IFM SI5100

Manufacturer

IFM

Country

Germany

Part number

SI5100

Description

Flow monitor with reliable monitoring of liquids and gases in pipes

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications SI5100

Variable process connection using adapters. Easy setting of the switch points for quick set-up. Robust stainless steel housing for use in harsh industrial environments. LED bar graph for indication of switch point and flow.

Features SI5100

Application
MediaLiquids, Gases, Aggressive media
Measured medium temperature [°C]-25…80
Pressure strength [bar]100
Liquids
Measured medium temperature [°C] -25…80
Gases
Measured medium temperature [°C] -25…80
Electronic data
Operating voltage [V]19…36 DC
Current consumption [mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs/outputs
Number of inputs and outputsNumber of digital outputs: 1
Outputs
Total number of outputs1
Output signalSwitching signal
Electrical versionPNP
Number of digital outputs1
Output functionnormally open / normally closed, (parameterizable)
Max. voltage drop of switching output DC [V]2.5
DC load current of switching output DC [mA]250
Short-circuit protectionyes
Short-circuit protection typeclocked
Overcurrent protectionyes
Measurement/setting range
Probe length L [mm]45
Liquids
Parameter setting within [cm/s]3…300
Max. sensitivity [cm/s]3…100
Gases
Parameter setting within [cm/s]200…3000
Max. sensitivity [cm/s]200…800
Accuracy/accuracy
Reproducibility [cm /s]1…5
Note about repeatability
for water 5…100 cm/s, 25 °C
Factory setting
Temperature drift [cm/s x 1/K]0.1, (for water 5…100 cm/s, 10…70 °C)
Max. temperature gradient (rate of change of medium temperature) [K/min]300
Switch point error [cm/ s]± 2…± 10, (for water 5…100 cm/s, 25 °C, factory setting)
Hysteresis [cm/ s]2…5, (for water 5…100 cm/s, 25 °C, factory setting)
Response time
Liquids
Response time [s]1…2, (for temperature gradient: 1 K/min)
Gases
Response time [s]1 …10
Software / Programs programming
Setting the switch pointProgramming buttons
Operating conditions
Ambient temperature [°C]-25…80
Storage temperature [°C]-25…100
Degree of protectionIP 67
Tests / approvals th>
EMC
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiation10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 RF conductance10 V
Impact resistance
DIN IEC 68 -2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (55…2000 Hz)
MTTF [years]298
Mechanical data
Weight [g]238
Dimensions [mm]M18 x 1.5
Thread designationM18 x 1.5
Materialstainless steel steel (1.4404 / 316L), stainless steel steel (1.4310 / 301), PC, PBT-GF20, EPDM/X mediumtitanium (3.7035), O-ring: FKM 80 Shore A
Process connectionM18 x 1.5 internal thread
Displays / Controls
Display
Function10 x LED, 3-colour
Remarks
RecommendationsPay attention to the change in compressive strength
Packing value1 piece
electrical connection
ConnectionConnector: 1 x M12