IFM GF711S
  IFM GF711S

We are not the manufacturer, authorised distributor or authorised representative of the IFM brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.

IFM GF711S

Manufacturer

IFM

Country

Germany

Part number

GF711S

Description

Fail-safe inductive sensor for ensuring machine safety

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications GF711S

Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849. No special actuator for electronic fail-safe sensors required. Connection to safety PLC, safe AS-i modules or safe evaluation units.

Features GF711S

Application
Operating modeContinuous operation (maintenance free)
Electronic data
Operating voltage [V]19.2…30 DC
Rated insulation voltage [V]30
Current consumption [mA]< 20< 20
Protection classIII
Reverse polarity protectionyes
Max. turn-on delay [ms]1000
Outputs
Electrical versionPNP
Output function2 x OSSD (A1 and A2)
Max. voltage drop switching output DC [V]2.5, (30 mA)
Direct load current switching output DC [mA]100
Output dataInterface type C class 1
Output voltage at 24 Bcompatible with Type 1, 2 inputs according to EN 61131-2
Short-circuit protectedyes
Overcurrent protectionNone
Max. capacitive load CL_max [nF]20
Control range
Target detection zone [mm] 0.5…4
Safe switch-off at distance s(ar) [mm]6
Response time
Safety time delay [ms]1
Response time when approaching the tripping zone [ms]1
Running time in the risk zone (response time to faults associated with security) [ms]20
Operating conditions
ApplicationClass C according to EN 60654-1 waterproof version
Ambient temperature [°C]-25…70
Ambient temperature note
Operating life ? 87600 h
Ambient temperature [°C]10…40
Ambient temperature note
Operating life ? 175200 h
Temperature change rate [K/min]0.5
Max. permissible relative humidity [%]short-term: 5…95%, permanent: 5…70%
Air pressure [kPa]80…106
Max. altitude [m]2000
Ionizing radiationnot allowed
Salt fogno
Degree of protectionIP 65, IP 67
Tests / Approvals
EMC
IEC 60947-5-2
IEC 60947-5-3
EN 60947- 5-3
EN 61000-4-2 ESD6 kV CD / 8 kV AD
EN 61000-4-3 RF emission20 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 RF Conductivity10 V
EN 61000-4-830 A/m
EN 55011Class B
Impact resistance
IEC 60947-5- 2
Vibration resistance< tbody>
IEC 60947-5-2
UL certified< tbody>
Ta-25…70 °C
Enclosure typeType 1
Supply VoltageLimited Voltage/Current
UL File NumberE174191
Safety classification
ISO 13849-1Category 2, PL d
IEC 61508SIL 2
IEC 62061SILCL 2
TM (Mission Time) [h]? 175200
TM service life (additional indication)
20 years
Reliability of the safety system PFHD [1/h]1.0E-07
Mechanical data
Weight [g]105.5
BodyThreaded body
InstallationNon-flush
Dimensions [mm]M12 x 1 / L = 70
Thread designationM12 x 1
Materialstainless steel steel (1.4404 / 316L), PBT (polybutylene terephthalate)
Displays / Operating elements
Display
operation mode1 x LED, green
Signal1 x LED, yellow
Accessories
Accessories (supplied)
fixing nuts: 2
Notes
Notes< tbody>
Unless otherwise stated, all data are based on a reference target according to IEC 60947-5-2 over the entire temperature range.
(FE360 = ST37K ) 12x12x1 mm
Packing quantity1 piece
electrical connection - connector
ConnectionConnector: 1 x M12, Contacts: gold-plated